The Schneider Electric Resi9 residual current device has 2 pole and its current rating is 25 A. It used type AC tripping characteristics which compliant with standards such as IEC/EN 61008-1 & 6100...
The Schneider Electric Resi9 residual current device has 2 pole and its current rating is 40 A. It used type AC tripping characteristics which compliant with standards such as IEC/EN 61008-1 & 6100...
The Schneider Electric 100A residual current breaker with overcurrent protection has a 60Hz of network frequency it has instantaneous protection time delay of earth leakage and It used 2P poles. It...
The Schneider Electric Resi9 residual current device has 2 pole and its current rating is 25 A. It used type AC tripping characteristics which compliant with standards such as IEC/EN 61008-1 & 6100...
The Schneider Electric Resi9 residual current device has 2 pole and its current rating is 25 A. It used type F-SI tripping characteristics which compliant with standards such as IEC/EN 61008-1 & 61...
The Schneider Electric ID series have residual current circuit breaker with 2 pole and it have 25 amp rated current. This RCCB have left neutral position. This RCCB have toggle control type and din...
The Schneider Electric ID series have residual current circuit breaker with 2 pole and it have 40 amp rated current. This RCCB have left neutral position. This RCCB have toggle control type and din...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 2 Range = Acti9 Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIDK Bett...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 4 Range = Acti9 Trip Sensitivity = 30mA Tripping Characteristics = Type A Voltage Rating = 380 → 415V ac Series = IID Mounting Sty...
Circuit Breaker Type = RCCB Current Rating = 25A Number of Poles = 2 Range = Acti9 Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIDK Bett...
Circuit Breaker Type = RCCB Current Rating = 25A Number of Poles = 1P+N Range = Acti9 Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIG40K...
The Schneider Electric ID series have residual current circuit breaker with 4 pole and it have 40 amp rated current. This RCCB have left neutral position. This RCCB have toggle control type and din...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 1P+N Range = Acti9 Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIG40K...
The Schneider Electric ID series have residual current circuit breaker with 2 pole and it have 40 amp rated current. This RCCB have left neutral position. This RCCB have toggle control type and din...
The Schneider Electric Resi9 residual current device has 2 pole and its current rating is 40 A. It used type F-SI tripping characteristics which compliant with standards such as IEC/EN 61008-1 & 61...
The Schneider Electric ID series have residual current circuit breaker with 4 pole and it have 40 amp rated current. This RCCB have left neutral position. This RCCB have toggle control type and din...
The Schneider Electric RCD have a Type AC tripping characteristic and an instantaneous break time. It has 1P+N pole version and can be DIN Rail mounted. It has 30mA of trip sensitivity and 25 A of ...
The Schneider Electrics Circuit trippers is an industry grade solution which is best suited for applications generally of motor, for their low cost and high performance. It employs Shunt Trip princ...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 2 Range = Acti9 Trip Sensitivity = 300mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIDK Bet...
Circuit Breaker Type = RCCB Current Rating = 25A Number of Poles = 2 Range = Acti9 Trip Sensitivity = 300mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIDK Bet...
The Schneider Electric Multi 9 GFP series is a Residual current circuit breaker (RCCB) with a Type A-SI Earth-leakage protection class. They are used for control and disconnection of electric circu...
Circuit Breaker Type = RCCB Current Rating = 40A Number of Poles = 1P+N Range = Acti9 Trip Sensitivity = 300mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIG40...
The Schneider Electric ID series have residual current circuit breaker with 2 pole and it have 40 amp rated current. This RCCB have left neutral position. This RCCB have toggle control type and din...
Acti9 iTG40 RCCBs. Acti9 iTG40 RCCBs limits wear and reduces voltage drops, helping to prevent premature equipment aging and overheating. VisiTrip indicates only the faulty outgoer, allowing fast d...
Circuit Breaker Type = RCCB Current Rating = 63A Number of Poles = 2 Range = Resi9 Trip Sensitivity = 30mA Tripping Characteristics = Type AC Voltage Rating = 230V ac Series = R9E
Circuit Breaker Type = RCD Current Rating = 25A Number of Poles = 1 Range = Acti9 Trip Sensitivity = 300mA Tripping Characteristics = Type AC Voltage Rating = 220 → 240V ac Series = Acti9 iIG40K Be...