Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 4 A Range = AF-1 Function = Motor Control Normal State Configuration = 2 NC, 5 NO
Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 4 A Range = AF-1 Function = Motor Control Normal State Configuration = 1 NC, 3 NO
Coil Voltage = 20 → 60 V DC Number of Poles = 3 Contact Current Rating = 4 A Range = AF-B - 1 Function = Motor Control Normal State Configuration = 1 NC, 3 NO
Coil Voltage = 20 → 60 V DC Number of Poles = 3 Contact Current Rating = 4 A Range = AF-B - 1 Function = Motor Control Normal State Configuration = 1NC, 3NO
Coil Voltage = 20 → 60 V DC Number of Poles = 3 Contact Current Rating = 4 A Range = AF-B - 1 Function = Motor Control Normal State Configuration = 4 NO
Coil Voltage = 20 → 60 V DC Number of Poles = 3 Contact Current Rating = 4 A Range = AF-1 Function = Motor Control Normal State Configuration = 2 NC, 5 NO
Coil Voltage = 48 → 130 V Number of Poles = 3 Contact Current Rating = 4 A Range = AF-B - 1 Function = Motor Control Normal State Configuration = 1 NC, 3 NO Length = 77mm
Coil Voltage = 24 V ac Number of Poles = 3 Contact Current Rating = 9 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 24 V dc Number of Poles = 3 Contact Current Rating = 9 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 400 V ac Number of Poles = 3 Contact Current Rating = 9 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 3N0/1NC
Coil Voltage = 230 V ac Number of Poles = 3 Contact Current Rating = 12 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 24 V ac Number of Poles = 3 Contact Current Rating = 12 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 230 V ac Number of Poles = 3 Contact Current Rating = 16 A Power Rating = 7.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 24 V ac Number of Poles = 3 Contact Current Rating = 16 A Power Rating = 7.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 24 V dc Number of Poles = 3 Contact Current Rating = 16 A Power Rating = 7.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 400 V ac Number of Poles = 3 Contact Current Rating = 16 A Power Rating = 7.5 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 400 V ac Number of Poles = 3 Contact Current Rating = 16 A Power Rating = 7.5 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 5N0/2NC
Coil Voltage = 100 to 250 V ac Number of Poles = 3 Contact Current Rating = 4 A Range = AF-B - 1 Function = Installation Contactor Normal State Configuration = 3NO
Coil Voltage = 20 → 60 V dc Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 3N0/2NC
Coil Voltage = 20 → 60 V dc Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 20 → 60 V dc Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 24 V dc Number of Poles = 3 Contact Current Rating = 24 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 24 V dc Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 240to 60 V Number of Poles = 3 Contact Current Rating = 4 A Range = AF-B - 1 Function = Installation Contactor Normal State Configuration = 3NO
Coil Voltage = 250 → 500 V Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 4kW Function = Control Unit Normal State Configuration = 3NO/1NC
Coil Voltage = 250 → 500 V Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 5N0/2NC
Coil Voltage = 250 → 500 V ac/dc Number of Poles = 3 Contact Current Rating = 25 A Series = 1SBL13 Function = Control Unit Normal State Configuration = 4NO Auxiliary Contact Configuration = 1NO
Coil Voltage = 48 → 130 V Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 4 kW Function = Control Unit Normal State Configuration = 4NO
Coil Voltage = 48 → 130 V Number of Poles = 3 Contact Current Rating = 25 A Power Rating = 5.5 kW Function = Control Unit Normal State Configuration = 3N0/1NC