Module Type = USB Interface Cable Output Signal Type = RS-232 Input Range = 1.6 → 5.6V Supply Voltage = 1.6 → 5.6V Mounting Type = Panel Mount Operating Temperature Range = -10 → +50°C Series = ACT...
ACT20X HUI-SAO-S/SAO-LP-S Signal Isolating Converter. The ACT20X HUI-SAO-S/SAO-LP universal measurement and signal isolating converters can be configured individually and has a relay output for con...
ACT20X HTI-SAO/2HTI-2SAO-S Signal Isolating Converter. The ACT20X HTI-SAO/2HTI-2SAO-S isolating converters record temperatures from PT100 sensors and thermocouples from Ex zone 0. Current loops fro...
ACT20X HTI-SAO/2HTI-2SAO-S Signal Isolating Converter. The ACT20X HTI-SAO/2HTI-2SAO-S isolating converters record temperatures from PT100 sensors and thermocouples from Ex zone 0. Current loops fro...
ACT20X SAI-HAO/2SAI-2HAO-S Signal Isolating Converter. ACT20X SAI-HAO/2SAI-2HAO-S current output isolating converters are suitable for controlling field devices in Ex areas, up to zone 0. The input...
Module Type = Signal Isolator Input Signal Type = Current Output Signal Type = Current Input Range = 4 → 20mA Output Range = 4 → 20mA Supply Voltage = 19.2 → 31.2V Hazardous Area Certification = IE...
ACT20X HAI-SAO/2HAI-2SAO-S Signal Isolating Converter. The ACT20X-HAI-SAO/2HAI-2SAO HART-protocol transparent current-supply isolating converters are capable of transmitting 4-20 mA signals from Ex...
Module Type = Signal Isolator Input Signal Type = Current Output Signal Type = Current Input Range = 4 → 20mA Output Range = 4 → 20mA Supply Voltage = 19.2 → 31.2V Hazardous Area Certification = IE...
ACT20X SDI-HDO/2SDI-2HDO-S Signal Isolating Converter. The ACT20X SDI-HDO/2SDI-2HDO-S valve control isolating converters are controlled from the safe zone on the input side by the switching signals...
ACT20X SDI-HDO/2SDI-2HDO-S Signal Isolating Converter. The ACT20X SDI-HDO/2SDI-2HDO-S valve control isolating converters are controlled from the safe zone on the input side by the switching signals...
ACT20X SDI-HDO/2SDI-2HDO-S Signal Isolating Converter. The ACT20X SDI-HDO/2SDI-2HDO-S valve control isolating converters are controlled from the safe zone on the input side by the switching signals...
ACT20X HDI-SDO-S/2HDI-2SDO-S Signal Isolating Converter. The ACT20X HDI-SDO-S/2HDI-2SDO-S isolating converters are specially designed for recording NAMUR sensor signals and digital switching signal...
ACT20X 2HDI-2SDO-RNC-S Signal Isolating Converter. The ACT20X 2HDI-2SDO-RNC-S isolating converters are specifically designed for recording NAMUR sensor signals and digital switching signals, which ...
ACT20X HDI-SDO-RNC/RNO-S/2HDI-2SDO-RNO-S Signal Isolating Converter. The ACT20X HDI-SDO-RNC-S/HDI-RNO-S/2HDI-2SDO-RNO-S isolating converters with amplifiers are specially designed for recording NAM...
ACT20X HDI-SDO-S/2HDI-2SDO-S Signal Isolating Converter. The ACT20X HDI-SDO-S/2HDI-2SDO-S isolating converters are specially designed for recording NAMUR sensor signals and digital switching signal...