The product image shows the Compact Support and Electrode assembly showing each elements assembled together. Please ensure you select the correct component for your individual requirement: Compact ...
This hydrostatic level probe allows to measure and control height of stable or moving liquid, concerning surface water (rivers, lakes, canals, muddy waters), thanks to its non-stick coating and its...
This hydrostatic level probe allows to measure and control height of stable or moving liquid, concerning surface water (rivers, lakes, canals, muddy waters), thanks to its non-stick coating and its...
This hydrostatic level probe allows to measure and control height of stable or moving liquid, concerning surface water (rivers, lakes, canals, muddy waters), thanks to its non-stick coating and its...
This hydrostatic level probe allows liquids measurement and monitoring in tanks, rivers and groundwater. The level measurement is carried out by measuring the differential pressure between the surf...
This hydrostatic level probe allows liquids measurement and monitoring in tanks, rivers and groundwater. The level measurement is carried out by measuring the differential pressure between the surf...
This hydrostatic level probe allows liquids measurement and monitoring in tanks, rivers and groundwater. The level measurement is carried out by measuring the differential pressure between the surf...
This tilt level switch has been designed to provide high level measurement in silos or any other type of storage containers located in non-hazardous areas. Its operation is very simple: Vertically ...
This tilt level switch has been designed to provide high level measurement in silos or any other type of storage containers located in non-hazardous areas. Its operation is very simple: Vertically ...
This ATEX certified tilt level switch (CertificationATEX II 1 D Ex ia IIC T6) has been designed to provide high level measurement in silos or any other type of storage containers located in hazardo...
This ATEX certified tilt level switch (CertificationATEX II 1 D Ex ia IIC T6) has been designed to provide high level measurement in silos or any other type of storage containers located in hazardo...
The SOLIBA M is a small membrane level detector for non-explosive areas which detects the high, low and / or intermediate level in the hoppers or small containers and the indications of stuffing in...
The SOLIBA M is a small membrane level detector for non-explosive areas which detects the high, low and / or intermediate level in the hoppers or small containers and the indications of stuffing in...
The SOLIBA M is a small membrane level detector for non-explosive areas which detects the high, low and / or intermediate level in the hoppers or small containers and the indications of stuffing in...
SOLIBA PRP rotary vane level sensors with plastic housing (ABS) are used to detect a high or low level of bulk products in storage silos, hoppers and containers. Placed on a hopper or silo, the SOL...
SOLIBA PRP rotary vane level sensors with plastic housing (ABS) are used to detect a high or low level of bulk products in storage silos, hoppers and containers. Placed on a hopper or silo, the SOL...
SOLIBA PRP rotary vane level sensors with plastic housing (ABS) are used to detect a high or low level of bulk products in storage silos, hoppers and containers. Placed on a hopper or silo, the SOL...
Device Type = Capacitive Sensor Mounting Type = Flush Mount Switch Output = PNP Body Material = PP Cable Length = 200mm Minimum Operating Temperature = -30°C Maximum Operating Temperature = +70°C S...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = 2x NPN/PNP Body Material = PBT Minimum Operating Temperature = -40°C Maximum Operating Temperature = +65°C Maximum DC Voltage = 30V dc...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = NPN/PNP, Analog 4-20mA Body Material = PBT Minimum Operating Temperature = -40°C Maximum Operating Temperature = +65°C Maximum DC Volt...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = NPN/PNP, Analog 0-10V Body Material = PBT Minimum Operating Temperature = -40°C Maximum Operating Temperature = +65°C Maximum DC Volta...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = 2x NPN/PNP Body Material = PBT Minimum Operating Temperature = -40°C Maximum Operating Temperature = +65°C Maximum DC Voltage = 30V dc...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = NPN/PNP, Analog 4-20mA Body Material = PBT Minimum Operating Temperature = -40°C Maximum Operating Temperature = +65°C Maximum DC Volt...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = 2x NPN/PNP Body Material = PBT Minimum Operating Temperature = -40°C Maximum Operating Temperature = +65°C Maximum DC Voltage = 30V dc...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = NPN/PNP, Analog 4-20mA Body Material = PBT Communication Protocol = IO-LINK°C Maximum Operating Temperature = +65°C Maximum DC Voltage...
Device Type = Radar Mounting Type = Barrel M30 Switch Output = NPN/PNP, Analog 0-10V Body Material = PBT Communication Protocol = IO-LINK°C Maximum Operating Temperature = +65°C Maximum DC Voltage ...
The Baumer point level detection based on frequency sweep technology for high-temperature hygienic application. It process temperature up to 200 °C and housing design with 360° status indicator for...
The Baumer point level detection based on frequency sweep technology for high-temperature hygienic application. It process temperature up to 200 °C and housing design with 360° status indicator for...
Device Type = Level Detector Mounting Type = Threaded Switch Output = PNP Body Material = Stainless Steel Minimum Operating Temperature = -40°C Maximum Operating Temperature = +85°C Maximum DC Volt...
Device Type = Level Detector Mounting Type = G1/2 Hygienic Switch Output = PNP Body Material = Stainless Steel Minimum Operating Temperature = -40°C Maximum Operating Temperature = +85°C Maximum DC...
Device Type = Liquid Level Sensor Mounting Type = Vertical/Horizontal Switch Output = PNP Body Material = Polysulfone Minimum Operating Temperature = 0°C Maximum Operating Temperature = +65°C Maxim...
Point level detection based on frequency sweep technology in the hygiene sector.Foam detection or suppression Problem solver for adhesions Two adjustable switching outputs 360° visible multi Colour...
Point level detection based on frequency sweep technology in the hygiene sector.Foam detection or suppression Problem solver for adhesions Two adjustable switching outputs 360° visible multi Colour...
Point level detection based on frequency sweep technology in the hygiene sector.Foam detection or suppression Problem solver for adhesions Two adjustable switching outputs 360° visible multi Colour...
Point level detection based on frequency sweep technology.Reliable in diverse media Wide variety of process connections For hygienic and industrial applications Process temperatures up to 200 °C
Point level detection based on frequency sweep technology.Reliable in diverse media Wide variety of process connections For hygienic and industrial applications Process temperatures up to 200 °C
Point level detection based on frequency sweep technology.Reliable in diverse media Wide variety of process connections For hygienic and industrial applications Process temperatures up to 200 °C
Point level detection based on frequency sweep technology.Reliable in diverse media Wide variety of process connections For hygienic and industrial applications Process temperatures up to 200 °C
Point level detection based on frequency sweep technology.Reliable in diverse media Wide variety of process connections For hygienic and industrial applications Process temperatures up to 200 °C
Point level detection based on frequency sweep technology for high-temperature hygienic applications.Process temperatures up to 200 °C Housing design with 360° status indicator For hygienic and ind...