Conforms to EN 50205. UL, CSA. 6A Relays with Forcibly Guided Contacts - G7SA. The slimline G7SA relay family with forcibly guided contacts is available as a four- or six-pole type in various conta...
The Omron G9SA series offers a line-up of compact and expandable safety relay units. It has main contact 4 and off-delay contacts 3. The off-delay time can be set between 0.5 to 7.5 s.Ambient opera...
The Omron G9SA series offers a line-up of compact and expandable safety relay units. It is expansion unit for G9SA series. It has main contact 3. The off-delay time can be set between 0.5 to 7.5 s....
The Omron G9SA series offers a line-up of compact and expandable safety relay units. It is expansion unit for G9SA series. It has main contact 3. The off-delay time can be set between 1 to 15 s.Amb...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN954-1, EN60204-1, UL508, CSA C22.2 No. 14. When ordering take note of the safety reset mode that is required: Models G9SB**A and G9SB ** B = Auto Reset operation; Models G9SB ** D = Manual Reset ...
EN ISO 13849-1: PLe/Safety Category 4, IEC 62061: SIL3, EN81-1/-2. CE, UL, TUV, CCC. Omron G9SE Safety Relay. The G9SE safety relay from Omron is ideal for a variety of safety input devices such as...
EN ISO 13849-1: PLe/Safety Category 4, IEC 62061: SIL3, EN81-1/-2. CE, UL, TUV, CCC. Omron G9SE Safety Relay. The G9SE safety relay from Omron is ideal for a variety of safety input devices such as...
EN ISO 13849-1: PLe/Safety Category 4, IEC 62061: SIL3, EN81-1/-2. CE, UL, TUV, CCC. Omron G9SE Safety Relay. The G9SE safety relay from Omron is ideal for a variety of safety input devices such as...
Supply Voltage = 24V dc Number of Channels = 2 Safety Contacts = 2 Auxiliary Contacts = 1 Reset Method = Automatic & Manual Range = Safety Relays Safety Category ISO 13849-1 = 4 PL ISO 13849-1 = e ...
Omron G9SR Configurable Safety Relay. The three models of the Omron G9SR safety relays cover virtually all common control system safety requirements in standalone applications. They feature front-p...
Omron G9SR Configurable Safety Relay. The three models of the Omron G9SR safety relays cover virtually all common control system safety requirements in standalone applications. They feature front-p...
EN 954-1. G9SX-GS, Safety Relays, Guard Switching. The G9SX-GS safety relay is designed to support maintenance mode and normal operation mode in a safe way. Two operation modes to support auto swit...
EN 954-1. G9SX-NS, Safety Relays, Electronic Non-contact Door Monitoring. The G9SX-NS safety relay is designed for electronic monitoring and control of non-contact door switches for enhanced stabil...
The Omron advanced unit 3 NO solid state outputs and 2 NO off delay solid state outputs.Logical AND function adds flexibility to various safety circuits It has TUV SUD certification for compliance
The Omron advanced unit 3 NO solid state outputs and 2 NO off delay solid state outputs.Logical AND function adds flexibility to various safety circuits It has TUV SUD certification for compliance
The Omron advanced unit 2 NO solid state outputs and 2 NO off delay solid state outputs.Logical AND function adds flexibility to various safety circuits It has TUV SUD certification for compliance
The Omron G9SX series basic unit has two safety outputs and has rated voltage of 24 V dc. It has spring-cage mounted terminals. It has maximum power consumption of 3 W. It has LED indicator for sig...
The Omron G9SX-N series is safety relay for D40A non-contact switches which has 2 instantaneous output. It has 24 V dc rated voltage. It has spring-cage mounted terminals.Degree of protection IP67 ...
The Omron G9SX-N series is safety relay for D40A non-contact switches which has 2 semiconductor outputs without delay and 2 semiconductor outputs with up to 3s delay. It has 24 V dc rated voltage. ...
The Omron G9SX-N series is safety relay for D40A non-contact switches which has 2 instantaneous and 2 timed output. It has 24 V dc rated voltage. It has spring-cage mounted terminals.Degree of prot...
The Omron G9SX series standstill monitoring unit based on back-EMF operation for two and three phase systems. It has 3 instantaneous semiconductor outputs and has spring cage mounted terminals.Read...
The Omron G9SX series standstill monitoring unit based on back-EMF operation for two and three phase systems. It has 3 instantaneous semiconductor outputs and has screw mounted terminals.Ready to u...