Maximum Time = 0.4s Minimum Time = 0.1s Maximum Operating Temperature = +50°C Minimum Operating Pressure = 2bar Maximum Operating Pressure = 8 bar Minimum Operating Temperature = -5°C
Crouzet Pneumatic TimerThe Crouzet 81 series pneumatic adjustable negative time delay module requires operating pressure ranging between 2bar and 8bar. This timer has a counting range from 0.1 seco...
Maximum Time = 15s Minimum Time = 0.1s Maximum Operating Temperature = +50°C Manufacturer Series = 81 Minimum Operating Pressure = 2bar Maximum Operating Pressure = 8 bar Minimum Operating Temperat...
Crouzet Pneumatic TimerThe Crouzet 81 series pneumatic adjustable positive time delay module requires operating pressure ranging between 2bar and 8bar. This timer has a counting range from 0.1 seco...
Maximum Time = 30s Minimum Time = 0.1s Maximum Operating Temperature = +50°C Manufacturer Series = 81 Minimum Operating Pressure = 2bar Maximum Operating Pressure = 8 bar Minimum Operating Temperat...
Adjustable Time Delay Module. On application of a pilot signal the reservoir starts to fill via the low restrictor. After the set time delay the relay is operated and an output is given. The timer ...
Crouzet Pneumatic TimerThe Crouzet 81 series adjustable frequency generator timer requires operating pressure ranging between 2bar and 8bar. This timer has a counting frequency range from 0.02Hz to...
Timer Relays. Adjustable timers, designed for pneumatic circuits. When a control signal "a" is emitted, the tank starts to fill up through the lower limiter. When the scheduled time has elapsed, th...
Maximum Time = 30s Minimum Time = 2s Hazardous Area Certification = ATEX Maximum Operating Temperature = +60°C Manufacturer Series = PZVT Maximum Operating Pressure = 6 bar
Maximum Time = 5s Minimum Time = 0.2s Maximum Operating Temperature = +80°C Minimum Operating Pressure = 2bar Maximum Operating Pressure = 10 bar Minimum Operating Temperature = +5°C
Impulse Generator. Fitted between a trip valve and directional control valve when it is necessary to eliminate a trapped or locked pilot signal that would otherwise prevent the control valve from r...
Maximum Time = 30s Minimum Time = 0.1s Maximum Operating Temperature = +60°C Manufacturer Series = PRT Minimum Operating Pressure = 3bar Maximum Operating Pressure = 8 bar Minimum Operating Tempera...
Maximum Time = 30s Minimum Time = 0.1s Maximum Operating Temperature = +60°C Manufacturer Series = PRT Minimum Operating Pressure = 3bar Maximum Operating Pressure = 8 bar Minimum Operating Tempera...
All logic units require mounting on a separate 2 or 3 port base, available separately. Logic units have an input (green) and output (red) pressure indicator to show the state of the respective sign...
Maximum Time = 3s Minimum Time = 0.1s Maximum Operating Temperature = +60°C Manufacturer Series = PRT Minimum Operating Pressure = 3bar Maximum Operating Pressure = 8 bar Minimum Operating Temperat...
Maximum Time = 180s Minimum Time = 10s Maximum Operating Temperature = +60°C Manufacturer Series = PRT Minimum Operating Pressure = 3bar Maximum Operating Pressure = 8 bar Minimum Operating Tempera...
Maximum Time = 60s Minimum Time = 0.5s Maximum Operating Temperature = +60°C Manufacturer Series = VR Minimum Operating Pressure = 0.1MPa Maximum Operating Pressure = 1 MPa Minimum Operating Temper...