Loop Impedance Test Type = Non Trip Earth Impedance Automatic RCD Test = Yes Model Number p = MW9325 Non-Tripping = Yes Insulation Test Voltage = 190 → 265V Earth Resistance Measurement = Yes Weigh...
RS PRO Automotive Relay Tester Introducing the RS PRO Automotive Relay Tester, also known as the Relay Buddy. It’s a high-quality device that can quickly give an indication of the general health an...
RS PRO Automotive Current Tester Introducing the RS PRO Automotive Current Tester, a high-quality device that is designed for quick and easy current detection and measurement of 20A dc current on b...
RS Pro MT-6600 Electrical Tester and Bluetooth Clamp Meter This exclusive 2 piece kit from our trusted and highly reliable RS PRO range includes the RS PRO multifunction electrical tester along wit...
Loop Impedance Test Type = Phase to Earth Model Number p = MET1000 Maximum Voltage Measurement = 1000V Test Type = Continuity Continuity Test Current = 3.5mA IP Rating = IP65 Power Source = Battery°C
Loop Impedance Test Type = High/Low Current Automatic RCD Test = Yes Model Number p = MFT-X1-AU Non-Tripping = Yes Insulation Test Voltage = 50 V dc, 100 V dc, 250 V dc, 500 V dc, 1000V dc Maximum ...
Loop Impedance Test Type = High/Low Current Automatic RCD Test = Yes Model Number p = MFT-X1-CH Non-Tripping = Yes Insulation Test Voltage = 50 V dc, 100 V dc, 250 V dc, 500 V dc, 1000V dc Maximum ...
Loop Impedance Test Type = High/Low Current Automatic RCD Test = Yes Model Number p = MFT-X1-SC Non-Tripping = Yes Insulation Test Voltage = 50 V dc, 100 V dc, 250 V dc, 500 V dc, 1000V dc Maximum ...
Loop Impedance Test Type = High/Low Current Automatic RCD Test = Yes Model Number p = MFT-X1-BS Non-Tripping = Yes Insulation Test Voltage = 50 V dc, 100 V dc, 250 V dc, 500 V dc, 1000V dc Maximum ...
The MFT1741 multifunction tester has been designed for testing low voltage electrical installations, particularly in locations that suffer from high electrical noise. It provides all the tests requ...
Megger Multifunction TesterThe Megger electrical tester is an MFT1800 series multifunction installation tester designed for testing low voltage of 100V, 250V,500V, 1000V with German mains plug. Thi...
TL17 test leads, 9V battery, K type thermocouple and instructions. ET5 Electrical Tester. The Martindale ET5 is a compact electrical tester for measuring voltage, resistance and current. The electr...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF XTRA Profi-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interface...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF XTRA Meister-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interfa...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF XTRA Starter-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interfa...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF XTRA 0105-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interface ...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF TECH EVSE-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interface ...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF TECH Meister-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interfa...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF TECH 0105-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interface ...
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF TECH Starter-Set Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interfa...
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = MED package XTRA IQ Non-Tripping = No Insulation Test Voltage = 400V
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = PROFiTEST MTECH+IQ EV Basic Packet Non-Tripping = Yes
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = PROFiTEST MTECH+ IQ E-Mobility Non-Tripping = Yes
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = Master Package TECH+ IQ Non-Tripping = Yes
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = Starter Package TECH+ IQ Non-Tripping = Yes
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = XTRA IQ Professional Package Non-Tripping = Yes
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = XTRA IQ Starter Package Non-Tripping = Yes
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF XTRA - LEMONGREEN Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interf...
Automatic RCD Test = No Model Number p = PROFiTEST MF TECH Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interface Type = USB
Loop Impedance Test Type = 4 Wire Automatic RCD Test = No Model Number p = PROFiTEST MF XTRA Non-Tripping = Yes Insulation Test Voltage = 600V Earth Resistance Measurement = Yes Interface Type = USB
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = PROFITEST PRIME AC Non-Tripping = Yes Downloadable Data = Yes
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes RCD Ramp Test = Yes Non-Tripping = No Insulation Test Voltage = 1000V
Loop Impedance Test Type = 2 Wire, 2 Wire (Non-Trip Range), 3 Wire Automatic RCD Test = Yes Model Number p = PROFITEST PRIME AC Non-Tripping = No Insulation Test Voltage = 1000V
Comprehensive operating instructions available on the Internet for download at www.gossenmetrawatt.com. Master package PROFITEST INTRO. Master package PROFiTEST INTRO, consisting of PROFiTEST INTRO...
Fluke T5-600, 62 MAX+ and 1AC II IR Thermometer, Electrical Tester and Voltage Detector Kit. This IR Thermometer, Electrical Tester and Voltage Detector Kit is designed to help electricians and HVA...