Assortiment
Mijn Mercateo
Aanmelden/Registreren
Winkelwagen
 
 

Pilz Dual-Channel Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock Safety Relay, 24V ac/dc, 3 Safety Contacts


Aantal:  stuk  
Productinformatie
Product Image
Product Image
Additonal Images
Additonal Images
Artikelnr.:
     3523E-9186686
Merk:
     Pilz
Fabrikantnr.:
     777301
EAN/GTIN:
     4046548071726
Zoekwoorden:
Remlichtschakelaar auto
Remlichtschakelaars auto
Lichtjeshemel
Lichtjeshemels
CE, cULus Listed, TÜV, KOSHA, CCC. PNOZX2.8P Safety Relay by PILZ. The PNOZX2.8P range of safety relays from PILZ offers you safety and performance of a top branded safety relay all in one. The PNOZX2.8P offers you different modes of operation such as single or dual channel switches. Suitable for several different applications which are listed below. Features and benefits:. DIN rail mounted with screw terminals LED display that offers you the following measures: - Supply voltages - Switch status Automatic reset Manual reset Detection of shorts across contacts or without Simple ; fast wiring Looping through of potential is possible quite easily Maintenance free thanks to the defined clamping force (no need for regular retightening). Safety features. The unit will monitor and measure and look out for an open circuit. If the circuit does open, the unit will immediately switch itself off to prevent hazards. Applications. Safety gate monitor Instantaneous E-STOP monitoring Limit switch Card reader Light beam device mon. Type 2 with t/p, Safe delay-on de-energ. timer. Technical safety parameters. EN 60204-1 EN 62061 EN ISO 13849-1 VDE 0113-1. How do Safety Relays work and what are they used for?. Safety Relays work by helping reduce unnecessary risk and hazard within your circuit. A typical circuit configuration may look like a production line where highly automated machinery works quickly, i.e. a production or packing line in a warehouse or factory. This line forms part of your 'circuit' and along that circuit you will have safety devices in place like emergency push buttons, safety curtains or pressure sensitive mats. To ensure complete safety in these environments, a safety relay can be added to your circuit to allow you full control and monitoring of your working environment. A safety relay will run regular checks down your circuit by sending pulses back and forth to confirm whether any (for example) wiring was implemented incorrectly or any welding has occurred along the circuit. Once the relay has detected this, it would then shut down the area by cutting off the power, until the fault can be determined and fixed. Most recent safety relays feature intuitive LED displays that will alert users to any faults, this is of course useful to prevent harm to users and also proactively engage in maintenance before any machinery is damaged beyond repair, so certain cost savings can be associated when using a safety relay. Some safety relays have specific functions and only work with certain devices like E-STOPs, some work better with other devices like safety curtains. More than one safety relay can be used to give you total monitoring of your circuit, ensuring you and your employees safety. What are the differences between a traditional 'relay' and a 'safety relay'?. A traditional relay will open and close your circuit and the switch devices down that line, however it will not monitor it in the same way a safety relay will and cannot automatically shut down specified areas to prevent harm to the machinery or workers. Safety relays are not prone to the same potential risks that traditional relays are and can be relied upon to monitor short circuit faults, ground faults or wire breakage. Offering a greater protection over their counterpart relays, they are specifically designed with your safety in mind. How do you operate a Safety Relay?. You must first align and wire the safety relay into your line and follow the setup instructions provided (will vary per manufacturer). Follow the onscreen instructions of the LED parallel to your instructions to perform integration into your circuit line. Depending on what parameters you set will determine the function of the safety relay (i.e. you tell it to cut off certain areas after certain criteria have been met, or you opt for a circuit wide halt of the line).
Meer informatie:
Supply Voltage:
24V ac/dc
Number of Channels:
2
Safety Contacts:
3
Function:
Emergency Stop, Light Beam/Curtain, Safety Switch/Interlock
Auxiliary Contacts:
1
Reset Method:
Automatic & Manual
Range:
PNOZ X
Safety Category (ISO 13849-1):
4
PL (ISO 13849-1):
e
SIL (IEC 61508):
3
Terminal Type:
Screw
Depth:
121mm
Series:
PNOZ X2.8P
Width:
22.5mm
Length:
94mm
Magazijnen (6)
Voorraad
Verzendkosten
Staffelprijs
Eenheidsprijs
^
13 werkdagen
Geen voorraad
€ 9,90*
vanaf € 189,96*
€ 202,74*
8 werkdagen
19
€ 7,90*
vanaf € 173,94*
€ 208,14*
€ 7,90*
vanaf € 173,82*
€ 208,14*
24 werkdagen
Geen voorraad
Franco huis
vanaf € 204,02*
€ 218,93*
Magazijn 3523
Franco huis
vanaf € 206,769*
€ 220,409*
Aantal:  stuk  
Prijzen: Magazijn 3523
Bestelhoeveelheid
excl. BTW
incl. BTW
Eenheid
1 stuk
€ 220,409*
€ 266,695
per stuk
vanaf 2 stuks
€ 220,149*
€ 266,38
per stuk
vanaf 5 stuks
€ 215,829*
€ 261,153
per stuk
vanaf 10 stuks
€ 214,389*
€ 259,411
per stuk
vanaf 500 stuks
€ 206,769*
€ 250,19
per stuk
Voorraad: Magazijn 3523
Verzendkosten: Magazijn 3523
Bekijk voorraad details hier.
Bestelwaarde
Verzendkosten
vanaf € 0,00*
Franco huis
Retourvoorwaarden: Magazijn 3523
Periode:Binnen 30 dagen
Toestand verpakking:Originele verpakking onbeschadigd, geopend
Toestand goederen:Ongebruikt
Verzendkosten:Gratis
Administratiekosten:Worden individueel vastgesteld
Conform de algemene voorwaarden en onafhankelijk van de retourvoorwaarden blijft de garantieperiode bestaan.
Accessoires
Wij hebben volgende accessoires:
Soort
Afbeelding
Artikelnaam
Fabrikant/nr.
Prijs excl. BTW
Accessoires
Weidmüller
514570000 (PACK OF 5)
vanaf € 23,82*
* Prijzen zijn excl. BTW en (indien van toepassing) incl. heffingen zoals Recupel, Bebat of Auvibel.
Mercateo verkoopt uitsluitend aan zakelijke klanten.